Plumbers NZ is New Zealand's largest online plumbing, gas and drainage resource. Plumbing exam help, plumbing news, directory and free quotes.

Author Topic: pressure reducing valve location???  (Read 4202 times)

0 Members and 1 Guest are viewing this topic.

Offline roberto

  • Full Member
  • ***
  • Posts: 168
  • Karma: +4/-0
pressure reducing valve location???
« on: June 06, 2012, 10:28:02 PM »
Would anyone recommend installing a prv in a ceiling to replace the supply tank or install it below the hwc in the cupboard?

I am going to increase the hot pressure for a costumer soon and thought I might make the hot and cold equal to the new shower mixer (methven celeste), by installing a 3 in one valve with a 3.7m prv and then combine the two outlets that are on the supply tank (cold feed to shower and to hwc), lagged of course

she has a open vented wetback system, was also thinking I might increase the hight of the hwc exaust??? :-X


cheers.

Linkback: https://www.plumbers.nz/ask-plumbers-trade/43/pressure-reducing-valve-location/1139/

Offline integrated

  • Sr. Member
  • ****
  • Posts: 412
  • Karma: +37/-2
Re: pressure reducing valve location???
« Reply #1 on: June 07, 2012, 05:53:03 PM »
i would throw it in with hwc - nothing worse than having to crawl through a ceiling space or under a floor to find and adjust a prv

gives better accessibility and better protection from freezing also 

Offline roberto

  • Full Member
  • ***
  • Posts: 168
  • Karma: +4/-0
Re: pressure reducing valve location???
« Reply #2 on: June 07, 2012, 08:52:33 PM »
yeah i see where ur coming from, i just want to avoid a unequal system,so I dont have to go back and put the jet back in the shower mixer that ive already taken out....


Offline integrated

  • Sr. Member
  • ****
  • Posts: 412
  • Karma: +37/-2
Re: pressure reducing valve location???
« Reply #3 on: June 07, 2012, 09:57:28 PM »
you can still do what you want to do depending on the existing plumbing



normally in my experience the high pressure feed to the ceiling tank and low pressure hwc feed went up/down through the hwc cupboard - if this is the case then:


- bridge the low pressure feed to the hwc and low presure feed to shower in the ceiling space
- use the old high pressure feeding ceiling tank that goes up inside hwc cupboard to supply 3in1 & prv to hwc inlet
- take a tee off after prv and connect to old low pressure feed to hwc which is now equal low pressure supply to shwr

should not have to touch hot supply unless installing temp valve then additional tee required (also after prv)

of course this all depends if pipework travels up/down hwc cupboard!!

Goodluck!!

Offline o2b007

  • Jr. Member
  • **
  • Posts: 77
  • Karma: +6/-0
  • time for change!!
Re: pressure reducing valve location???
« Reply #4 on: June 08, 2012, 08:32:21 AM »
I would check how the wetback is feed, If it is a clossed loop it will also be feed off the header tank otherwise intergrated has it bang on.
oh and if there is no tempering valve you should talk them into putting one in just make sure that it suitable for the wetback.

Offline roberto

  • Full Member
  • ***
  • Posts: 168
  • Karma: +4/-0
Re: pressure reducing valve location???
« Reply #5 on: June 09, 2012, 09:22:26 AM »
hey, no its not a closed loop wetback, there are uncommon here.

Offline qeplumbing@gmail.com

  • Jr. Member
  • **
  • Posts: 10
  • Karma: +3/-0
  • Im new @ Plumbers NZ!
Re: pressure reducing valve location???
« Reply #6 on: October 28, 2012, 01:17:23 PM »
Keep in mind that the pressure from the prv to the cylinder will increase by about  2m head pressure once going through the prv dropping down to the cylinder.
 Always a lot to keep in mind with maintenance on older systems hey mate!! :)
Best to put it in a location close as possible to the cylinder.


Share via digg Share via facebook Share via linkedin Share via twitter

Similar Topics

  Subject / Started by Replies / Views Last post
xx
pressure reducing valve

Started by mefozzy

2 Replies
1568 Views
Last post December 04, 2014, 11:19:59 PM
by CristyCMcAlister
xx
pressure relief valve

Started by tsenior

11 Replies
13433 Views
Last post September 09, 2014, 08:23:04 PM
by integrated
xx
mains pressure valve conversion problem

Started by bentley

4 Replies
7080 Views
Last post September 18, 2010, 12:05:20 AM
by bentley
clip
Pressure relief valve in roof space

Started by CraigD

0 Replies
1290 Views
Last post February 09, 2021, 05:36:55 PM
by CraigD
 
Share this topic...
In a forum
(BBCode)
In a site/blog
(HTML)